Skip to content

VC365 for fuel retail Every Station. Every Detail.

AI-powered visual checks for forecourts, tanks, stores and service bays, mapped to the fuel-safety, environmental and brand standards you work to.

Built for

  • Forecourt and dispensers
  • Tanks and deliveries
  • Convenience store and food
  • Car wash and service bays
  • EV charging and new fuels
  • Dealer and franchise networks

Why it matters

A Brand Promise Is Kept One Small Check at a Time

A nozzle docked. A hose without cracks. A fill-point lid closed. An extinguisher within reach. VC365 turns each into a live, photo-backed check tied to the exact station and asset, so the people who decide can see every forecourt without driving to it.

  • Many stations, few managers

    Each check is tied to a station and an asset by QR label, with a time-stamped record of who did it and on which shift.

  • Shifts and dealers

    Tasks belong to roles. Attendants and operators change; the checks and their history do not.

  • Open to the public

    A safety-critical check never passes or fails on AI alone. A person confirms.

How it works

From Observation to Action

One loop, shown here on a single hose check on a forecourt round.

  1. 01

    Define

    A “Forecourt round” SOP: the checks, the schedule, the role.

  2. 02

    Capture

    An attendant scans the nozzle label and photographs the hose.

  3. 03

    Understand

    AI notes a crack near the nozzle end. The result is FAIL.

  4. 04

    Improve

    A corrective action, a recheck, a verified close.

Example checks

Visual Checks for Fuel Retail

Each one is an atomic check: one visible question, with an example photo, a schedule and the role that does it. Copy them, change them, or write your own.

  • Nozzle docked

    Each nozzle back in its holster, checked per nozzle.

  • Hose and breakaway condition

    No visible cracks, kinks or leaks.

  • Delivery area set up

    Cones out, earthing connected, extinguisher at hand.

  • Correct fill point

    Product label and hose connection photographed before discharge.

  • Tank gauge console

    Display photographed, alarms noted.

  • Chiller and freezer temperature

    Display photographed, reading checked against the limit.

  • Charger screen and status

    Working, legible and free of fault messages.

  • Licences and certificates

    On display and legible, expiry date read.

Scheduling

The Right Check. At the Right Time.

Stations run on shifts, deliveries and peaks. Each SOP is scheduled by station and role, so the right checks appear when the work does.

  1. Opening

    At shift start

    Uniform and identification · Forecourt clean and lit · Fire points accessible · Price display matches

  2. Rounds

    Every few hours

    Nozzles docked · Hoses and breakaways · Dispenser fronts clean · Spill kit in place

  3. Delivery

    When the tanker arrives

    Area coned off · Earthing connected · Right hose on the right fill point · Lids closed after

  4. Closing

    At shift change

    Washrooms · Store and chillers · Lighting and signage · Waste cleared

  5. Periodic

    Weekly and monthly

    Extinguisher tags · Meter seals and verification marks · Sumps and separator · Licence on display

Example schedule. You choose the checks, times and roles. A check nobody did in time is Missed, and is never counted as failed.

Standards

One Check. Many Standards.

Eleven everyday forecourt checks, the fire-code chapter each one supports, and the matching workplace-safety references.

One Check. Many Standards.: each atomic check and the requirements it helps evidence
Atomic checkNFPA and API referenceUS OSHA 29 CFRISO 45001
Nozzle docked, hose free of cracksNFPA 30A · Ch. 61910.106(g)8.1
Breakaway coupling intactNFPA 30A · Ch. 61910.106(g)8.1.2
Emergency stop signed and accessibleNFPA 30A · Ch. 61910.106(g)8.2
Fire extinguishers in reach and in dateNFPA 30A · Ch. 9, NFPA 101910.1578.2
Warning signs displayedNFPA 30A · Ch. 91910.106(g)8.1.2
Spill kit and absorbent stockedNFPA 30A · Ch. 9—8.2
Delivery area coned off and earthedAPI RP 1007—8.1.2
Forecourt free of spills and trip hazards—1910.228.1
Electrical covers and area labels intactNFPA 30A · Ch. 81910.3078.1.2
Uniform, footwear and hi-vis—1910.1328.1.2
Exits and assembly point signed—1910.37, 1910.388.2

Indicative mapping. References point to the clause family each check supports. Confirm them against the current text and with your certification body or regulator. VC365 produces the evidence; it does not certify compliance.

Standards these checks can be mapped to

  • NFPA 30A
  • US OSHA 29 CFR 1910.106(g)
  • US EPA 40 CFR Part 280
  • ISO 45001:2018
  • ISO 14001:2015
  • API RP 1007 and API RP 1621
  • PEI RP900 and RP1200
  • APEA/EI Blue Book
  • EN 13617, EN 13012 and EN 1360
  • OIML R 117

Your segment

Where VC365 Fits in Fuel Retail

The same platform, set up for the way each part of the sector works.

  • Forecourt and dispensers

    From the Forecourt to Each Nozzle

    The forecourt is where customers judge the brand and where most of the hazards sit. VC365 models each dispenser down to its nozzles and hoses, so a fault is raised on the exact part that needs attention.

    • Nozzle docked
    • Hose and breakaway condition
    • Dispenser fronts and displays
    • Forecourt surface
    • Canopy, signage and lighting
    • Fire points and emergency stop
  • Tanks and fuel deliveries

    Below Ground. Still in View.

    Most of a station’s environmental risk sits underground and arrives by tanker. What can be seen becomes a scheduled, photographed record: fill points, sumps, vents, the gauge console and the delivery set-up.

    • Delivery area set up
    • Correct fill point
    • Fill-point spill containers
    • Tank gauge console
    • Dispenser and tank sumps
    • Vent pipes and separator
  • Convenience store and food

    The Store Sells. The Standard Shows.

    At many stations the store and the food counter matter as much as the fuel. The same app checks chillers, hot food, washrooms and shelves, to food-safety and brand standards.

    • Chiller and freezer temperature
    • Hot-food holding
    • Date labels and rotation
    • Coffee and food counter
    • Washroom condition
    • Shelves and promotions
  • Car wash and service bays

    More Services. The Same Discipline.

    Car washes, lube bays and tyre points add moving machinery, chemicals and waste to the site. VC365 gives each its own short routine and its own history.

    • Car-wash emergency stop and signs
    • Chemical store
    • Used oil and filters
    • Vehicle lift inspection tag
    • Air and water points
    • Bay housekeeping
  • EV charging and new fuels

    New Energy. Familiar Checks.

    Chargers, LPG, CNG and hydrogen bring new equipment onto the same forecourt. Each gets its own assets, labels and visual checks, alongside the liquid-fuel routine.

    • Charger screen and status
    • Cables and connectors
    • Bay markings and bollards
    • Gas hoses and couplings
    • Gas-area signage and barriers
    • Emergency shut-off points
  • Dealer and franchise networks

    Many Operators. One Brand Standard.

    Most networks mix company-run and dealer-run stations. VC365 holds every operator to the same checks, so territory managers compare like with like and visit where it matters.

    • Brand presentation
    • Uniform and identification
    • Promotional material
    • Licences and certificates
    • Customer facilities
    • Territory manager visit

In action

From a Cracked Hose to a Verified Fix

One exception, followed from the photo to closure. Because the check is High severity, the AI flags it and a person decides.

  1. 01

    Captured

    An attendant scans Nozzle N-03 and photographs the hose.

  2. 02

    Flagged

    AI sees a crack near the nozzle end. High, so it goes to a person.

  3. 03

    Confirmed

    The station manager confirms FAIL. A finding opens.

  4. 04

    Verified

    New evidence shows the replaced hose.

Illustrative example with sample data. The original finding stays on record.

Honest by design

Know the Limits

VC365 produces and assesses evidence. Certification stays with you and accredited bodies, and a picture only shows what is visible.

  • Missed is not failed

    A skipped check and a check found wrong are different problems, counted separately.

  • People decide on doubt

    AI never fails a High or Critical check alone, and an AI outage never becomes PASS or FAIL.

  • VC365 complements leak detection, wet-stock monitoring and your maintenance programme. It replaces none of them.

  • A QR scan supports traceability. It is not, by itself, conclusive proof of a physical inspection.

  • A photo shows a hose’s outer condition. It does not replace pressure testing or scheduled replacement.

  • A photo of a console or a dry sump records what was visible. It does not replace tightness testing, calibration or verification by an authorised body.

  • A photographed seal or verification mark shows that it is present. Meter accuracy is verified by the metrology authority.

  • Phone use on the forecourt follows your site rules and local regulation.

FAQ

VC365 for Fuel Retail: Questions Buyers Ask

Can VC365 check every nozzle and hose on a dispenser?

Yes. Each dispenser is modelled down to its nozzles and hoses, and scanning the QR label opens exactly the checks that belong to it. A cracked hose on one nozzle raises one finding, not a failed dispenser.

Is VC365 a leak-detection or wet-stock system?

No. VC365 evidences visible conditions such as spill containers, sumps and the gauge console. It complements leak detection, wet-stock monitoring and your maintenance programme, and replaces none of them.

Can dealer-run stations use the same checks?

Yes. Company and dealer stations run one set of checks and are compared fairly, and each dealer sees and closes its own findings.

Is it safe to use a phone on the forecourt?

VC365 works within your site rules on where and when photos may be taken. Many operators and regulators restrict phone use near dispensers and fill points, and that follows your site rules and local regulation.

Does it work without a signal?

Yes. It is designed for up to 72 hours offline; work is marked as queued and syncs when back online.

Does VC365 certify compliance with NFPA 30A or EPA rules?

No. Checks can be mapped to references such as NFPA 30A, OSHA 29 CFR 1910.106(g) and US EPA 40 CFR Part 280, and the mapping is indicative. VC365 produces the evidence; it does not certify compliance.

See VC365 on Your Fuel Retail SOPs

Book a demo and we will walk through your procedures with you, or create your organisation and start with one site today.